🔧 Common problems and error codes
1. No charging
2. Reverse polarity
Error code: E01 – Reverse polarity
3. Overheating
-
High ambient temperature
-
Poor ventilation
-
Internal charger fault
Error code: E02 – Overtemperature
4. Battery defective
Error code: E03 – Battery cannot store charge
5. No battery detected
-
Battery not connected
-
Voltage below 1V
-
Loose clamps
Error code: E04 – No battery detected
🔄 Charging process – 10 stages
-
Connection analysis
-
Desulphation
-
Soft start
-
Controlled current charge
-
Charging analysis
-
Constant output charge
-
Recovery cycle
-
Absorption
-
Voltage retention check
-
Maintenance mode
🔧 Repair Mode
🛠 Quick troubleshooting
-
Check mains power
-
Check polarity
-
Measure battery voltage
-
Test on another battery
-
Activate repair mode
We stock the most commonly requested spare parts. Please state model and spare part number when enquiring.
|