Typical errors on COMPRESSOR
[Kompressor]
Typical errors on COMPRESSOR
Click to enlarge

🔧 Common faults and what they mean

1. Compressor does not start

Possible causes

  • No power / blown fuse

  • Faulty pressure switch

  • Tank pressure too high

  • Faulty motor or worn brushes

  • Defective start capacitor

  • Low voltage

  • Motor protection tripped

Check

  • Verify power supply

  • Release pressure from tank

  • Listen for click from pressure switch

  • Measure voltage

  • Check capacitor

Solution

  • Replace capacitor

  • Replace pressure switch

  • Check power supply

  • Motor service/repair


2. Compressor hums but does not start

Causes

  • Faulty start capacitor

  • Low mains voltage

  • Extension cable too long/thin

  • Motor seized

  • High back pressure

Check

  • Connect directly to outlet

  • Test capacitor

  • Empty tank pressure

Solution

  • Replace capacitor

  • Use correct cable

  • Check motor


3. Compressor starts and stops quickly

Causes

  • Faulty pressure switch

  • Air leak

  • Faulty check valve

  • Overheating

  • Overload

Check

  • Listen for leaks

  • Use soap water on fittings

  • Check pressure switch

Solution

  • Repair leaks

  • Replace check valve

  • Adjust pressure switch


4. Compressor runs continuously

Causes

  • Air leak in system

  • Air consumption too high

  • Worn piston rings/valves

  • Faulty pressure switch

  • Clogged air filter

Check

  • Check air tool consumption

  • Check pressure build-up

  • Listen for leaks

Solution

  • Clean filter

  • Fix leaks

  • Pump service

  • Replace valves


5. Compressor does not build pressure

Causes

  • Air leak

  • Faulty check valve

  • Worn piston rings

  • Valve plate failure

  • Blocked intake filter

Solution

  • Repair leak

  • Replace valve plate

  • Replace rings

  • Clean filter


6. Safety valve releases air

Causes

  • Pressure too high

  • Faulty pressure switch

  • Faulty safety valve

Solution

  • Adjust pressure switch

  • Replace valve

⚠️ Never ignore this fault.


7. Compressor overheating

Causes

  • Poor ventilation

  • Dirty cooling fins

  • Long runtime

  • High load

  • High ambient temperature

Solution

  • Ensure airflow around unit

  • Clean cooling fins

  • Allow cooling breaks


8. Water in air system

Causes

  • Condensation in tank

  • Tank not drained

Solution

  • Drain tank regularly

  • Use water separator


9. Compressor shuts off during operation

Causes

  • Motor overload protection

  • Overheating

  • Voltage drop

Solution

  • Let unit cool

  • Check power supply

  • Reduce load


10. Unstable operation / vibration

Causes

  • Loose bolts

  • Worn bearings

  • Uneven surface

Solution

  • Tighten bolts

  • Replace bearings

  • Place on stable surface


Typical spare parts

  • Pressure switch

  • Start capacitor

  • Check valve

  • Safety valve

  • Air filter

  • Motor

  • Valve plate

  • Piston rings

  • Pressure gauge

  • Hoses/fittings


Quick check (before service)

  1. Check power supply

  2. Drain tank

  3. Check air filter

  4. Listen for leaks

  5. Check pressure build-up

  6. Check temperature

This resolves approx. 60% of faults.


When to contact service

  • Burnt motor

  • No pressure build-up

  • Electrical failure

  • Inverter compressor fault

  • Damaged pump unit


Quick rule of thumb

No start → power/capacitor
Humming → capacitor
Runs constantly → leak
Overheats → ventilation
No pressure → valves/piston
Safety valve blows → pressure switch